Microcomputer controlled pressure testing machine for pipes
Current Category: Specialized testing machine
Name: Microcomputer Controlled Pipe Pressure Test Machine
Model: ZNY-5
Specification: Maximum pressure: 20MPa
Anchor 1.2 Function Overview
The microcomputer controlled pipe pressure testing machine consists of a dual CPU control system with the same pressure control method as Denmark. The upper computer mainly completes graphic processing, data processing, and data management, while the lower computer controls the pressure system to achieve the target pressure according to the pressure rate based on the instructions of the upper computer. The test process is controlled by a microcomputer, which displays pressure values, test time, and test status in real time. The data is processed and analyzed by a microcomputer, and the test results can be automatically saved, exported, and printed. This machine is a testing equipment that determines the pressure resistance and instantaneous burst pressure of bathroom fittings such as pipes, faucets, braided pipes, ball valves, angle valves, gate valves, fittings joints, PVC pipes, etc. within the pressure range according to national standards. It is widely used in factories, product quality inspection units, scientific research institutions and other units to test, inspect and develop the pressure resistance and burst test performance of pipes and pressure vessels.
|
Specification and Model |
|
|
Maximum pressure (MPa) |
20 |
|
Test temperature |
Room temperature |
|
Test medium |
Clean water |
|
Pressure range |
0.2~20.0MPa (adjustable as desired) |
|
Constant voltage accuracy |
-1~+2% |
|
Accurate pressure display |
0.001MPa |
|
Test time (h) |
10000 |
|
Overall dimensions of the host (length×); Width× Height (mm) |
Approximately 700× 600× 1800 (6 routes and below) |
|
Host power supply power (kW) |
380V、1.5kw |
|
Weight (kg) |
200 |
|
Water tank technical indicators |
|
|
Water tank control range |
Room temperature~97 degrees |
|
Water tank temperature control accuracy |
± 0.5℃ |
|
Uniformity of water tank temperature |
± 0.5℃ |
|
Water tank temperature resolution |
0.1℃ |
|
Water tank safety |
Configure short-circuit protection device, made of stainless steel material |
|
Thickness of insulation layer for water tank |
Greater than 83mm, less than 95mm |
|
Appearance of constant temperature water tank |
1000*800*1300mm |
|
Water tank power supply power (kW) |
AC380V、18kw |